The gas water heater does not light up: why it does not light up and does not turn on, the causes of breakdowns, why it goes out and does not work when the water is turned on

Scope of geysers Electrolux

Due to the almost irreplaceable properties and features of the devices of the declared brand, upon purchase you get a truly high-quality model, which is accompanied only by positive feedback from the owners. Nevertheless, heating equipment is used not only in domestic conditions, but also in many other industries (of course, more powerful models are used for such cases).

If you choose the right gas water heater, then one heating of water will be enough to completely buy the whole family.
If you choose the right gas water heater, then one heating of water will be enough to completely buy the whole family.

Gas water heaters can be found for heating water in hospitals, workshops, gyms, swimming pools and many other places where workers are accustomed to hygiene. Usually, these devices handle large displacement, and for industrial conditions, models with maximum performance will be needed.

The main advantages and disadvantages of gas columns Electrolux

You can trust Electrolux as it has gained popularity due to the durability of the equipment.
You can trust Electrolux as it has gained popularity due to the durability of the equipment.
Let us dwell in more detail on what positive qualities Electrolux gas columns have.

  • safety of technology. The device can prevent a fire hazard by means of a residual current device installed in models of the middle price segment;
  • maximum savings. Choosing even the most budgetary option for a gas water heater, you can be sure that it will use fuel efficiently and heat the water to the optimum temperature;
  • additional options to choose from... Choose models with interesting features without hindrance. Sooner or later, you will want to use the indicators or the flame control window;
  • long service life... Despite the long warranty period (about 5 years), devices from the Electrolux trademark have been successfully operating for tens of years after its warranty;
  • nice design. There is absolutely nothing superfluous on the body of the device: a streamlined shape without flaws and well-fitting controls are ideally combined with each other;
  • convenient use. Whether the control function is electronic or mechanical, both have proven themselves well among owners.

For ten years, the brand has been showing itself as a supplier of incredibly reliable and flawless equipment to the CIS countries and Russia.

In addition to gas workers, subject to a proper license, a company selling equipment can also connect a gas water heater.
In addition to gas workers, subject to a proper license, a company selling equipment can also connect a gas water heater. GOOD TO KNOW!

If the organization of the local gas industry has presented you with requirements for obtaining permission to use the Electrolux gas water heaters, you can legally refuse this. Remember that connecting the device is free, you only need to pay for maintenance and provide a passport for the geyser model.

Gas water heater Electrolux - and why do Russians choose it?

We were a little distracted, but let's return to what can upset you as an accomplished owner of the Electrolux gas water heater.

  • uncomfortable water heating... If most boilers have a heating tank, then there is no such option in gas water heaters from the Electrolux manufacturer. The technique heats the water in a flowing way: everyone will need to go swimming at once one after the other;
  • heavy firing... In the absence of the necessary traction, it will be difficult to ignite the device. Sometimes this can even cause the installed piezo to break;
  • does not work at low water pressure... If you live in the private sector, and someone often waters the gardens from a common water supply, then in the evening a low water pressure is noticed. In such conditions, the gas water heater is unable to work. To avoid such inconveniences, the owners additionally install a pump.

So, we have discussed all the qualities that are useful to study before buying a device. Of course, in addition to this, it is important to understand for what specific purposes a gas boiler is being bought, and then focus on all possible characteristics.

With a stable water supply, one unit of equipment is capable of handling several water intake points.
With a stable water supply, one unit of equipment is capable of handling several water intake points.

The gas water heater does not turn on: reasons

The failure of the gas water heater can be associated with both external factors (for example, mechanical damage), and with disruptions in the operation of individual components of the column. The most common problem faced by the owners of gas water heating equipment is the refusal of the device to work when the water is turned on. Why doesn't the speaker turn on? There may be several reasons.

So, the gas water heater may not turn on when water is supplied due to:

  • Low water pressure. This is the most common reason. You can check the pressure by opening any cold water supply tap.
  • Clogged pipeline. Low water pressure can be caused by blockages in the pipes. In order to fix the problem, you should contact the ZhEK. It is the ZhEK who must monitor the health of the water supply lines.
  • Malfunctions of the water intake unit of the gas equipment. We are talking here about a mesh filter and a membrane, which are located at the inlet of the water unit. The filter can be both mechanically damaged and clogged with lime deposits.

In addition, the ignition of the column may not turn on due to insufficient ventilation draft. This can be caused by both clogging of the air duct and the ventilation duct. The first malfunction can be eliminated by hand. To do this, you need to dismantle and clean the chimney. The second problem can only be eliminated by specialists.

The device and the basic principle of operation of gas heaters Electrolux

Many irreplaceable elements are involved in the design of the Electrolux gas heater. During the activation of the toggle switches, the incoming water is heated through the water pipes. At the outlet of the column, we get hot water right in the tap, just turn the mixer to the red mark.

See the detailed diagram of the Electrolux column with the description below.
See the detailed diagram of the Electrolux column with the description below.

We propose to study in detail the scheme of the Electrolux gas column with a description of each working module involved in water heating.

  1. Control block... It is a small mechanism that contains the levers and toggle switches required to operate the appliance. The main function of this module is to monitor the temperature range and heater performance.
  2. Device for regulating water and gas supply. The declared system ensures perfect safety control of the gas water heater. The system will initiate an automatic shutdown when the gas pressure is low or there is no water supply.
  3. Modulating burner - regulates the height of the flame, and when the pressure drops, it is able to maintain the temperature of the water.
  4. Copper heat exchanger... It helps to transfer heat from the heated gas to the water in the tubes without loss. It is characterized by increased wall thickness.
  5. Power Supply... A device that is present in every electrical appliance. Responsible for supplying energy.

On the basis of such a simple scheme, Electrolux geysers operate. However, it is not necessary to equate all devices to one template, since each model can be slightly upgraded.

Each gas heater has a drain valve, but it should only be used when dismantling equipment.
Each gas heater has a drain valve, but it should only be used when dismantling equipment.

GOOD TO KNOW!

Don't know with what kind of ignition to buy the device? Our editors recommend the electric piezo technique. This option will help out at a time when there are no matches at hand, and you need to turn on the heater desperately.

Gas water heater Electrolux - and why do Russians choose it?

External factors of malfunction

What to do if the gas column does not light up? Failures in the operation of the gas column can be caused by circumstances beyond its control. Let's consider them in order:

Gas supply

Gas cut-off
There is not much to talk about here, and everything is clear: if the gas is turned off, the water heater will not work.

Just do not rush to blame the gas workers for everything.

If there is a filter in the system, first check that it is not clogged.

Water pipes

Here are some surprises that a water supply system can present:

The piping was connected incorrectly.

It is a very likely reason, especially if an amateur is taken to install the column. If the newly installed water heater refuses to work, check the connection diagram again.

Insufficient head

Small water pressure
Some of the gas water heaters are equipped with an ignition system that is driven by a stream of water - it rotates a turbine connected to a piezoelectric element.

With a weak head, of course, such a system will be inoperative.

The opening of the gas valve is also carried out by water pressure - through the membrane, which was mentioned above. If the water is barely flowing, the valve will remain tightly closed.

Most often, pressure problems occur in rural areas. When buying a column, their residents should definitely specify at what minimum pressure it can work.

However, even in urban conditions, the pressure in the pipe may turn out to be scanty. The reason is the clogging of the strainer installed in front of the column. To test this hypothesis, turn on the cold water tap on the mixer. If the pressure here is normal, then the problem is really local in nature - you need to check the mesh filter or heat exchanger (more on this below).

Inlet water temperature has risen

Some users, out of inexperience, forget to take into account the fact that the water in the water supply becomes warmer with the beginning of the spring-summer season. If the column remains set for winter mode, it will constantly turn off due to overheating.

Smoke exhaust system

Column chimney
In the absence of draft in the chimney, the protective automatics, despite all your admonitions, will not allow you to use the column.

For example, if the chimney is clogged, the gas water heater will not ignite.

External reasons that may worsen the outflow of combustion products include the following:

  1. Chimney clogged: debris or poultry can enter the flue gas duct. In addition, over time, it becomes overgrown with soot, so it needs periodic cleaning.
  2. Installation above the chimney head of large objects: in most cases, such an object becomes a television satellite dish. It prevents the free flow of gases, to which the draft sensor immediately reacts.
  3. Lack of outside air flow: the user should not forget that for normal draft, it is necessary to provide air supply to the room from the outside. When the column is working, at least the window must be open. This is especially true for sealed glass units in metal-plastic frames.
  4. Unfavorable weather conditions: the column can also go out due to the fact that a strong wind or vortex worsens the thrust or, conversely, sharply increases it, causing the flame to separate.

The presence of traction is checked by bringing a column of paper sheet or a lighted match to the "viewing window". With the proper condition of the smoke exhaust system, the flame will be drawn into the "window", and the paper will be pressed against it.

Review of geysers Electrolux with customer reviews and current prices

Surely you are already thinking about purchasing the equipment of an eminent brand.Before heading to the mall, be sure to check out our selection of the models on sale today. The editors of Tehno.guru responsibly approached the creation of this review and found real reviews from the owners, but more about everything.

Electrolux GWH 265 ERN NanoPlus - reliable instantaneous water heater

Oxygen FREE technology ensures there is no harmful contact between lead and oxygen.
Oxygen FREE technology ensures there is no harmful contact between lead and oxygen.
A device with a stainless steel burner, good power and excellent performance. That's all a big family needs. In addition, the technique will cope with the provision of hot water supply, regardless of how many points are connected to it.

Treatment volume, l / minThermal power, kWControl methodWater heating temperature, С °Additional features
1017,80mechanical75Indicators, display, thermometer.

Electrolux GWH 265 ERN NanoPlus

Electrolux GWH 11 PRO Inverter - gas water heater, easy to set up

The sensitivity of the temperature sensors will not allow setting an incorrect value in the absence of water pressure.
The sensitivity of the temperature sensors will not allow setting an incorrect value in the absence of water pressure.
Excellent technology, suitable for both large houses and small apartments. The device is equipped with an open combustion chamber, which makes it easy to dispose of waste.

Treatment volume, l / min.Thermal power, kWControl methodTemperature supportAdditional features
1122electronicYesDisplay, thermometer, self-diagnosis.

Electrolux GWH 11 PRO Inverter

The geyser Electrolux GWH 10 High Performance is made of quality materials

The gas safety valve is triggered when the gas pressure rises and releases it to optimum values.
The gas safety valve is triggered when the gas pressure rises and releases it to optimum values.
Decent design and compact dimensions - what else do you need to place an appliance in a bathroom or equipped kitchen? These are the qualities that the declared heater model possesses.

Water heating volume, l / min.Thermal power, kWControl methodThe presence of a piezoAdditional features
1020electronicYesProtection systems, power indicator, thermometer

Electrolux GWH 10 High Performance

Gas column Electrolux GWH 10 NanoPlus 2.0 with a high heating rate

The model of an affordable price category has optimal parameters for domestic use.
The model of an affordable price category has optimal parameters for domestic use.
The good build quality of the device will not let the user down, even if he regularly dismantles it when moving. However, it will continue to work after re-installation without the need for additional settings.

Water heating volume, l / min.Thermal power, kWControl methodProtection functionsAdditional options
1020electronicGas control, overheating protection, work without water.Heating and power indicator, display, temperature range limitation.

Electrolux GWH

Pay attention to the models presented in the previous section. They are in demand, as shown by the positive feedback from the owners. In addition, the editors of Tehno.guru also analyzed the capabilities of each of the devices, and advises to give preference to the declared devices when purchasing.

The gas water heater works with claps

Possible reasons:

  1. Most likely, there was a problem with the temperature sensor installed to protect the column from overheating.
  2. If the column works normally for a short time, and then turns off by itself, and it turns out to be re-ignited only after 15–20 minutes, then the sensor is too sensitive to temperature. The fault in this may be the initial malfunction of the part or the stuffiness in the room.
  3. If the column works intermittently (sometimes without complaints, and sometimes it turns off for no reason): the insulation of the conductor of the temperature sensor is probably worn out.

Decision:

  1. Ventilate the room where the speaker is located. Maybe the kitchen is just too hot.
  2. Replace the temperature sensor (this can be done under warranty if the column was purchased recently).
  3. Contact the service center about the problem.

Possible reasons:

  1. Gas pressure too high.
  2. Gas pressure too low.

Solution: The burner needs to be cleaned and adjusted. This is not difficult if you know the theory. But it is better to call a specialist.

Which is better to buy a gas water heater Electrolux: we will evaluate the important parameters

It is also not worth dwelling on the popularity of models alone. Our experts urge the user to accurately determine the key specifications to meet your expectations. So, what are the things to look out for in order not to become a victim of an unwanted purchase?

Design and power - how will they change for different areas of the premises

For houses with large dimensions, different models of Electrolux equipment are suitable - the main thing is that they have high power (from 28 kW) and be able to handle up to several water intake points. This is welcome in country houses and dachas. At the same time, it is not necessary to be limited to restrained design. If there is a financial opportunity, you can purchase a model to order.

Pay attention to the need for regular cleaning of the gas column nozzles. Devices with maximum power clog up especially quickly.
Pay attention to the need for regular cleaning of the gas column nozzles. Devices with maximum power clog up especially quickly.

If you are making a purchase of water heaters with a proposed installation in a small kitchen, then the best indicator would be a power of up to 24 kW. This is quite enough to heat water in a small "Khrushchev".

Which way of control and ignition is better for a gas water heater

If you had to see a gas water heater from friends or relatives, you were probably given all sorts of advice on how to operate it. Which way it is more convenient to control the column - using flat touch buttons or using the rotation of knobs and toggle switches - is up to you.

When installing gas water heaters at home, remember the need to use three-phase wiring.
When installing gas water heaters at home, remember the need to use three-phase wiring.

Regarding the electronic control of Electrolux gas water heaters, we can say the following: they do not tolerate contact with moisture. You cannot go to the appliance and increase the temperature immediately after washing the dishes until you dry your hands. But mechanical handles work even in damp conditions - but should they be subjected to this once again?

The type of ignition of gas water heaters is conventionally divided into three types:

  • starting with a piezo;
  • electric ignition (using batteries);
  • from open fire (matches, lighter).

Each of the methods for turning on the device is good in its own way, but it can also bring some inconveniences. For example, it is impossible to ignite a column without electricity if the element is a piezo component; after discharging the batteries, you will also not be able to cope with starting the equipment. The only alternative remains - the use of matches for lighting. Again, they should always be in the house.

Geysers are suitable for any type of chimney, the main thing is that it has good throughput and no blockage in the channel.
Geysers are suitable for any type of chimney, the main thing is that it has good throughput and no blockage in the channel.

Gas water heater safety

What is this property? Almost every second buyer asks such a question. The safety of the device operation lies precisely in the presence of additional protective capabilities:

  • thermostat to prevent overheating of the device;
  • protective shutdown in the event of a drop in gas or water pressure;
  • a check valve that relieves pressure if it goes beyond the normal range and threatens with an explosion;
  • a protective shutdown (built-in RCD) is useful in case a power failure occurs.

It is a mistake to think that the gas water heater works only on blue fuel. It also needs electricity to function properly.
It is a mistake to think that the gas water heater works only on "blue fuel". It also needs electricity to function properly.

The Dion gas column does not light up: we determine the shortcomings

Both the comfort and the safety of all residents of the house depend on the correct operation of gas equipment.One of the most common causes of fire hazardous situations is the lack of ignition in the column. At the same time, the equipment can turn on, but go out after 2-3 minutes of proper operation. In this case, the problem is most often associated with a lack of sufficient traction.

In addition, the column may not light up if:

  • The cold water pressure is higher than the hot water pressure. In this case, it will be enough to adjust the thrust force.
  • Broken ionization sensor. In this case, the column will work after turning on for only a few seconds. At the same time, ignition sparks will go quite often. If the Dion column does not ignite for this reason, the electrode will need to be cleaned.
  • During operation, the solenoid valve or servomotor has worn out. This breakdown will be signaled by “claps” when the column is turned on. If the column does not start for this reason, then the elements will need to be replaced. You should first clean the ignition wick: the problem may lie in its clogging.

Operating instructions for gas water heaters Electrolux

Installation, first start-up, maintenance - all these are the main and very important components of the use of gas water heaters. If you miss a moment or turn on the device incorrectly, there is a risk of a dangerous situation. To prevent this from happening, you need to know all the subtleties of use that can be learned in our guide.

Be vigilant when starting up columns that do not have a shutdown sensor when excess gas comes out.
Be vigilant when starting up columns that do not have a shutdown sensor when excess gas comes out.

Features of turning on the Electrolux heater

To start a gas heater, you do not need to have any special knowledge, you just need to follow safety precautions and not create an emergency. Our editorial staff offers the following video to help the user, which shows how to start the device and configure the operating mode.

Proper care of gas water heaters from Electrolux

Repair and maintenance of gas water heaters is carried out directly by service specialists. The user should not disassemble and dismantle the device unnecessarily, especially when trying to find out how the mechanism works inside.

Do not repair the device if you do not understand anything about it. It is unsafe to do this without proper education, even using video from the Internet.
Do not repair the device if you do not understand anything about it. It is unsafe to do this without proper education, even using video from the Internet.

In addition, as the owner, you should know some recommendations regarding the care of the gas water heater.

  1. Keeping the appliance perfectly clean. Wipe off dust regularly and prevent moisture and condensation from settling - this is especially true for equipment in the kitchen. And if this happens, try to dry everything quickly.
  2. Do not cover the device with rags and other objects, do not store trinkets and souvenirs on top.
  3. During operation, the unit does not need to be wiped with a damp cloth and general cleaning is required. When the column is hot, the wet enamel becomes yellow.
  4. If the heater blows out frequently, determine what the problem is - and, if necessary, call the technician. Never try to fix something inside with sharp objects.

The burned-out elements of the gas column must be urgently replaced; it is unsafe to use the device in this state.
The burned-out elements of the gas column must be urgently replaced; it is unsafe to use the device in this state.
In short, treat the appliances exactly as you would other types of equipment in your home. Then you will surely not run into problems of functioning for many years.

Repair of the water heater Ariston

A common malfunction of this model, however, like similar ones, is no flame due to failure of the water membrane... If the rubber is damaged, then this element will not be able to squeeze the stem for gas supply.

In this case, remove the part and use it to purchase a new membrane from a specialized store, and then replace it. To remove the damaged membrane, first disconnect the water pipelines from the column, remove the heat exchanger and the cover of the water unit, under which the membrane is located.

If the water flow pressure is too low, it will be impossible to start the Ariston column. The minimum value should be at a reading of 0.4 atm. The water pressure regulator knob is usually marked with a blue stripe.

If the permissible draft in the chimney is violated, a signal will be sent from the corresponding sensor to the control panel. In this case, it will not be possible to start the water heater until the malfunction is eliminated. The burner flame will ignite, but after a few seconds the fire will go out. Traction is usually checked with a lit candle or a match.

iwarm.decorexpro.com/en/