Instructions for the installation, operation and maintenance of gas water heaters


How to turn on the gas water heater KGI 56

The first thing to do is to open the gas and cold liquid valves to the column. Check the presence of traction, for this take a small piece of paper and bring it to the hood. If the draft is good, it should snuggle up to the duct.

Further:

  1. Move the left lever to the leftmost position.
  2. Use a burning match to light the wick, wait 10-15 seconds for the bimetallic fire sensor to work.
  3. Turn on any hot water taps in your home.

Then turn the right knob to the right, by this action you will light the main burner. With this lever you can adjust the water heating temperature. It is strongly not recommended to regulate its heating by dilution in a mixer, as high temperatures lead to the formation of scale on the walls of the heat exchanger.

Thus, it turns out that when you open the hot water tap, the main burner automatically lights up from the igniter and the liquid starts heating.


Gas column burner KGI 56

Be careful when you open the valve with hot liquid, very hot water will flow for the first 5-10 seconds, and then the set temperature will flow. This is normal and due to the design of the speaker.

The gas water heater KGI-56 is blowing

Thank you!

Here's what I found on self-repair KGI-56:

We have already talked about the gas explosion on the street. Chemists. As a result of the explosion, a resident of the apartment was hospitalized, a woman living on the floor above was killed and the apartment building was significantly damaged. And this story has received a logical continuation. According to the results of the investigation, an 80-year-old resident of the apartment in which the explosion took place was charged with the fact that he independently carried out repairs of his KGI-56 gas water heater and the result of his actions led to death by negligence. Now Nikolay P.'s case has been sent to the Efremovskiy District Court.

The prosecutor's office of the Tula region opened a criminal case under Art. 109 of the Criminal Code of the Russian Federation (causing death by negligence) on the fact of an explosion of household gas in Efremov. The explosion, as a result of which one person died and one was injured, the inter-apartment wall collapsed and two apartments burned out, occurred on November 13 at 13:25 in apartment No. 63, located on the first floor of apartment building No. 8 on the street. Chemists of the district town of Efremov. As the deputy prosecutor of the region Vasily Poslovsky, who visited the scene, told RG, according to the main version, the cause of death of 57-year-old Valentina Kulikova was carbon monoxide poisoning, and not the fall of the wall, as was originally supposed. Currently, the cause of death is being investigated. Presumably the culprit of the explosion was her neighbor, 80-year-old pensioner Podkolzin, who started an independent repair of the gas water heater. Now he is in a regional hospital with a head injury and burns to his extremities. As a result of the explosion, in addition to the collapse of the concrete wall between apartments, glass was broken in the neighboring apartments and on the staircase, the balcony of the second floor was damaged, and there was a threat of collapse of the interfloor overlap. All residents of neighboring apartments were promptly evacuated on the same day. They were offered to stay in a local hostel for a while, but no one took advantage of this offer - everyone went to their relatives. Currently, work is underway to eliminate the consequences of the explosion; over the past weekend, the ceiling has been strengthened. The authorities promise that people will be able to return to their apartments in the coming days

writes "Rossiyskaya Gazeta" According to my information, the man really climbed to repair the column. There are several reasons for this, but the main one is that in order for the municipal services to monitor the equipment inside the apartment, residents need to conclude an agreement and pay money for it.And an 80-year-old pensioner probably counts every penny. This is how we live ...

How a working column should work

The instructions for the KGI 56 gas water heater contain the following conditions:

  • If the main burner is not turned on, that is, the liquid is not heated, the ignition wick should burn with a low flame. The color of the flame should be blue and the noise should be low.
  • When opening a tap with hot water, the device should not turn on suddenly, there should be no sound of popping or explosion.
  • There must be no soot when operating the main burner.


    Gas water heater KGI 56 with an open casing

  • If you close the tap at the point of drawing, the device should go out immediately, there should be no delay of more than 5-7 seconds.
  • There should be no spontaneous shutdowns of the column during operation.
  • The heating temperature should be regulated from warm to boiling water.

If at least one of the points is not met, then the device is faulty and needs to be repaired. For stable operation, it is necessary to carry out scheduled repairs and inspections every year.

It is necessary to regularly wipe the device from dust and other contaminants, also as needed. Before starting any work on the device, disconnect it from gas and water by shutting off the valves.

How to turn on a gas column KGI 56

The first thing to do is to open the valves to supply gas and cold liquid to the column. It is necessary to check the presence of traction, for this you need to take a small piece of paper and bring it to the hood. If the traction is good, he should snuggle up to the air channel.

  1. Move the left stick all the way to the left.
  2. Use a burning match to light the wick, wait 10-15 seconds for the bimetallic fire meter to work.
  3. Open any of the taps with hot water
    in the House.

Then turn the right knob to the right, by this action you will light the main burner. With this lever, you will be able to adjust the temperature of the water heating. It is highly not recommended to adjust its heating by dilution in a mixer, since high temperatures lead to the appearance of scale on the walls of the heat exchanger.

Similarly, it turns out that when you turn on the tap with hot water

, the main burner is automatically ignited from the ignition wick and the liquid begins to heat up.

Gas column burner KGI 56

Be careful, when you open the valve with hot liquid, very hot water will flow for the first 5-10 seconds, and then it will flow at the set temperature. This is a good thing and is due to the design of the speaker.

Manufacturer - Russia

AURORA

AURORA
- Instructions for the installation and operation of the gas water heater

ASTER

Instructions for the installation and operation of the gas water heater ASTRA 8910
execution 00.02execution 08.028910-158910-16

VPG-TGA, Taganrog Gas Apparatus

Instructions for the installation and operation of the gas water heater TGA
VPG-6VPG-8VPG-10VPG-12

Master Gaz Comfort, Armavir

Installation and operation instructions for the Master Gaz Comfort gas water heater
Master Gaz Comfort 10Master Gaz Comfort 12

NEVA

Installation and operation instructions for the NEVA geyser
3208 (VPG-18)40114510461045114513

NEVA LUX

Installation and operation instructions for the geyser NEVA LUX
501150135014501650255028551355145611601160136014

Russian woman, Voronezh

Rossiyanka-M
- Instructions for the installation and operation of the gas water heater

Halsen (Halsen)

Instructions for the installation and operation of the Halsen gas water heater
Halsen WM 10Halsen WM 12

Manufacturer - Germany

AEG

Instructions for the installation and operation of the gas water heater AEG
GWH 6E N13GWH 11E N13GWH 11RNGWH 14RN

JUNKERS (Junkers) BOSCH (Bosch)

BOSCH Neckar JSD20 ⁄ 26 - B23BOSCH Neckar JSD20 ⁄ 26 - B31
Installation and operation instructions for the JUNKERS BOSCH WR gas water heater
10-2B13-2B15-2B10-2G13-2G15-2G10-2P13-2P15-2P275350400
Installation and operation instructions for the BOSCH Therm gas water heater
200040006000 S8000 S

VAILLANT (Vilant)

Installation and operation instructions for the VAILLANT atmoMAG geyser
14-0 / 0 RXZ14-0 / 0 RXI14-0 / 0 GRX
Installation and operation instructions for the VAILLANT MAG geyser
pro 11-0 / 0 XZC +OE 19/2 XZ-C +remium SOE 19 / 2-24 / 2 XIPpremium SOE 19 / 2-24 / 2 XIpremium OE 19 / 2-24 / 2 XZpremium OE 24/2 RXIpremium OE 24/2 RXZ
Installation and operation instructions for the VAILLANT GEYSER MAG geyser
275/12 XZ350/12 XZ440/12 XZ

Gas column KGI-56

Column KGI-56 has long been discontinued, but consumers even nowadays have a certain amount of these devices. Structural simplicity, reliability and availability of spare parts lead to the fact that KGI-56 is still in operation.

Important technical properties:

  • heat load - 24,000 kcal / hour;
  • water pressure - 0.5 - 6 kgf / cm? (bar);
  • productivity - 10 l / min.

KGI-56 has a powerful key burner, but low efficiency, which determines its low productivity.

Thermal valve diagram KGI-56

The heat exchanger (heater) KGI-56 has a high fire chamber, surrounded by a coil, which is soldered to the "jacket". The KGI-56 burner is single-nozzle, which led to the high fire chamber of the heater, which is needed for the complete combustion of gas. In the KGI-56 burner, not very good mixing of the gas with the primary air occurs, due to which the flame is lengthened. The burner is equipped with a flame control (thermal valve), consisting of ignition wick

and a bimetallic plate on which the valve is suspended (Fig. 72). When the bimetallic plate is heated by the ignition wick, it bends, and the valve opens the gas passage to the burner. When extinguished
ignition wick the plate cools, straightens, the valve closes the gas passage to key burner
.

The block valve consists of gas and water parts, which are fixed to each other with three screws. The block valve provides gas supply to key burner if there is a complex of facilities for the intake of water and its shutdown when the complex of facilities for the intake of water is terminated (automation through the water flow).

ignition wick

There are two cone valves in the gas section: one changes the gas supply to key burner

and the other on the ignition wick. In the tap on
key burner
a poppet valve is supplied, which opens the gas supply under the influence of the stem
water part
... A small spring presses on the valve from above, a large spring serves to fix the plug in the body.

IN water part a membrane cloth is clamped between the cover and the body, on which the plate with the stem rests. Cool water is supplied to water part from below. Through a hole with a diameter of 3.3 mm, cold water pressure is supplied to the under-membrane space water part

block crane. Therefore, the pressure under the membrane tissue is equal to the water pressure in the water meter assembly. Then the water goes through the heater and returns to the water part. In this case, the water that is heated transfers pressure through a hole with a diameter of 2 mm to water filling the supra-membrane space. This pressure during the flow of water through the column will always be less than that which presses on the membrane tissue from below, due to the difference in the diameters of the holes in the sub- and supra-membrane space and losses due to friction. With the duct, the membrane tissue bends upward, pushing out the plate with the stem. The stem lifts the valve above the plug seat of the gas part of the block valve, overcoming the action on the valve from above by a small spring and opening the gas passage from the inner void of the plug to the burner. When the flow of water stops, the pressure under the membrane tissue and above the membrane tissue is leveled, the membrane tissue stops raising the stem. The valve, under the influence of a small spring, will close the gas passage. There is no automatic traction control on the KGI-56 dispenser.

Manufacturer - Turkey

Avangard (Vanguard)

Installation and operation instructions for the Avangard gas column
C-125-BC-150-SC-275-BC-275-SC-275-SEC-275-SEIC-350-SC-350-SEI

DEMRAD

Installation and operation instructions for the DEMRAD gas water heater
C-125-BC-150-SC-275-BC-275-SC-275-SEC-275-SEIC-350-SC-350-SEI

Manufacturer - Italy

ARISTON

Installation and operation instructions for the ARISTON Fast gas water heater
GIWH 10 EAGIWH 13 EAGIWH 10 PAGIWH 13 PAGIWH 16 PA11 CF E14 CF E11 CF P14 CF P

Beretta IDRABAGNO (Idrabagno)

Installation and operation instructions for the Beretta gas water heater
IDRABAGNO-11IDRABAGNO-11iIDRABAGNO-14IDRABAGNO-14iIDRABAGNO-17IDRABAGNO-17i

Ferroli Prometeo

Installation and operation instructions for the Ferroli Prometeo gas water heater
E-10 PCM-5CL-7CL-11CL-13CL-156CIP-11CIP-13CIP-156

Manufacturer - China

Akvilon (Aquilon)

Akvilon gas water heater installation and operation manual
AM-20SAM-20GAM-20WAM-24SAM-24GAM-24W

Neva Transit

Instructions for the installation and operation of the Neva Tranzit gas water heater
10EA12EA14EA

Edisson

Installation and operation instructions for the Edisson gas column
S20S20GF20DF20GD

Oasis

Installation and operation instructions for the Oasis geyser
ISD12-A1ISD16-A1ISD20-A1ISD24-A1ISD26-A1

ORION

Installation and operation instructions for the ORION JSD gas water heater
14-D14-DS14 – DV20 – D20 – DS20 – DV20 – DK20 – DKS20 – DKV

Maxi Proton (Proton)

Maxi Proton 10L
- Instructions for the installation and operation of the gas water heater

Selena

Installation and operation instructions for the Selena SWH gas water heater
20-E120-E220-E320-SE120-SE2

Termaxi, China

Installation and operation instructions for the Termaxi JSD geyser
14-L20-W20-W-A1

Vektor

Installation and operation instructions for the Vektor JSD geyser
11-N12-W20-E20-W

Zanussi (Zanussi)

Installation and operation instructions for the Zanussi gas water heater
Zanussi gwh fonteZanussi GWH Fonte Glass
iwarm.decorexpro.com/en/

Warming

Boilers

Radiators