Heating private houses and apartments with water-heated floors is a fairly popular option, since the system is efficient and economical. Warm air rises evenly from bottom to top, creating optimal comfort in the room. Warm floors can be implemented in different ways, it can be a warm floor from central heating in an apartment or an electric one that requires laying a heating cable. Considering the cost of electricity, many residents find the idea of installing a floor heating from a battery in an apartment more attractive. The costs will mainly be for equipment, while heating costs will not be so high.
Is it legal to connect to a district heating system?
It is widely believed that connecting a warm floor from hot water in an apartment or from a heating radiator is strictly prohibited. This is not entirely true. A permit from the management company can be obtained if the apartment is located at the end of the heating circuit - on the first or last floor, depending on the heat supply scheme. Thus, the heat energy received in the apartment will not infringe on other residents in the apartment building. As a rule, you need to install a heat energy meter, and you can safely connect the warm floor from the battery.
The supply of heat energy is carried out through a heat exchanger for the warm floor in the apartment, which allows you to make the underfloor heating circuit "autonomous", not affecting other heat consumers.
What problems can arise?
Before making underfloor heating powered by a hot battery, it is necessary to consider the difficulties that the master may face:
- Temperature difference of water in the system. It should be borne in mind that the maximum heating parameters of the warm floor are 50 degrees, while in the heating system this value is 70-90 degrees. If you connect the structure directly, the equipment may be damaged and the floor covering may be damaged.
- A ban on the installation of underfloor heating in apartments with centralized heating. If the inspection body finds the structure, the owner of the living quarters may be punished with a fairly large fine.
- If an elevator was used to connect the heating, then only copper pipes can be used for the equipment of a warm floor, and they are quite complex and expensive to install.
How will the height of the room change from the installation of a warm floor?
When planning to install a warm floor from heating in an apartment, you need to think over not only the cost of materials, obtaining a permit. An important nuance is to take into account how the floor height rises. It is necessary to install good thermal insulation on the subfloor so that the heat does not go into the floor slabs. For apartments on the second and higher floors, it is enough to install 3 cm of insulation (polystyrene, etc.).
If the heated floor in the bathroom from the heated towel rail is connected on the first floor, below which there is a basement or ground, the insulation layer should be within 5-10 cm. Next, the size of the pipes, the topcoat layer are taken into account. The result is the final figure by which the height of the room will be reduced. If the living space allows, you can buy equipment.
When is it forbidden to install warm floors in an apartment?
It is forbidden to install underfloor heating from heating, if you thereby lead to the destabilization of the warm and hydraulic balance between neighboring apartments along a common heating riser. In other words, this is when each room has a separate heating riser.
If it is so that it is strictly forbidden to install warm water floors, as this can lead to the fact that your warm water floor connected to this riser is able to take off the temperature so much that it will significantly reduce the heat that passes to other apartments using this riser. But, practically and theoretically, water heated floors can be installed anywhere and anywhere, the main thing is that the balance of the water flow is not disturbed, and the conditions for dosing the heat consumption are observed.
Underfloor heating pipes
Considering that water floor heating is filled with a screed, it is clear that you need to choose durable pipes. The choice of a specific material will directly affect the price of 1 sq. M of warm water floors.
But the price is not the main thing, it is important to comply with the conditions:
- It is not allowed to use seam pipes, they may burst if the pressure increases. The same applies to a large number of joints in the underfloor heating circuit - this is a potential cause of blockage, leaks.
- We need strong pipes that can withstand both the pressure of the coolant, and the severity of the screed, and dynamic loads (the benchmark is pressure resistance of at least 8 bar).
- High indicators of resistance of pipes to corrosion, chemicals, scale, as well as sound insulation (so as not to hear the noise from the movement of water) are important.
- The diameter of the pipes varies between 16-20mm (too thin pipes will increase pressure, thick ones will increase heat loss in the general heating system). Before connecting the warm floor to the existing heating, it is worth considering the presence of adapters, fittings of suitable sizes.
Electric floor heating permit
The device of such a floor is not included in the list of prohibited ones, and it is also not on the list of mandatory approval. However, if underfloor heating is installed in an apartment located in a house with insufficient electrical power, problems remain. This category includes all houses, except for new buildings.
In the old days, houses were built with a power grid designed for the minimum number of electrical appliances, and the old wiring does not withstand the use of modern appliances, including the use of an electric floor. For underfloor heating, it is necessary to replace the wiring and the distribution board.
The housing inspectorate must provide a certificate of the power of the device, confirming that the warm floor will not cause overloads in the network. Such a certificate will remove responsibility in case of any problems with the electrical network. Such a certificate must be obtained from the management company serving the house where this redevelopment is planned.
If there is not enough power, the electric floor cannot be installed. New buildings have a significant power reserve, it is easier to legalize warm electric floors there.
What is needed to connect a warm floor?
You can't just take and cut the contours of the underfloor heating into the heating risers. The water will not circulate on its own, so a pump will be needed. A system is also required to remove accumulated air in the system. The coolant in centralized heating is not clean, therefore, to protect your own underfloor heating system, you need to install filters that trap dirt particles.
It is important to take into account that the coolant in centralized heating can be heated up to 80 degrees, and you cannot put such water into your system - this will ruin both the screed and the topcoat, and it will be excessively hot in the room.
The optimum temperature of the coolant in the underfloor heating system is up to 45 degrees.
Therefore, it is necessary to install a unit that mixes water from the supply and return, as well as devices that control the parameters. Therefore, the price of a warm floor will include the price of a temperature sensor for a warm floor, a thermal head, and a servo drive, etc.
How to make underfloor heating from central heating through a separate entrance
It is worth making a reservation right away that no matter what scheme you choose, a lot will depend on the quality of the coolant in the central network.So, in the water floor system there are a large number of needle valves, and if there are solid particles in the water, they can seriously clog the pipeline and lead to its breakdown.
Typically, the water floor pipes are welded to the central heating manifold. This scheme has its advantages:
- a coolant with a constant temperature is supplied to the collector of the home system thanks to the installation of a special thermostatic valve;
- in addition, the required temperature can be set using a three-way valve, also equipped with a thermostat;
- and the installation of a special bypass also ensures a minimum water flow after the valves are closed.
We recommend: What kind of warm floor is better to put under the tiles?
However, in such a heating circuit, it is required to protect the circulation pump from running the latter dry. This can be done by regulating pressure or flow. In addition, an overhead thermostat is often used, which turns off the pump when the temperature drops to 20 degrees Celsius. And in order to control the system more reliably, instead of a thermostatic valve, you can install a special regulator that adjusts the temperature of the coolant depending on the temperature in the room.
Using vertical layout
This method is based on the reconstruction of the existing radiator system. As you know, each radiator has its own limits for the flow rate of the coolant. The latter are usually set using an adjustment valve.
Underfloor heating scheme from central heating
In fact, when connected to a hot water riser, you can get twice as much heat as from conventional radiators. This is due to the fact that in the supply and return pipelines, the temperature is usually about two times higher than in the pipes of the water floor. And therefore, if the apartment, for example, has four risers, then hot water can be taken from two, and the coolant can transit from the rest. Typically, such a system consists of the following elements:
- risers of a two-pipe heating system;
- balancing valve;
- actuator for a three-way valve;
- three-way valve.
However, to implement such a scheme, you will have to replace the old batteries with new heat exchangers. This cannot affect the hydraulic operation of the riser in any way, since the settings of the balancing valves will remain the same.
In this case, the secondary circuit of the water floor is connected in parallel. If balancing heat exchangers in the second circuit is problematic, then PVC pipes of the same length should be used.
Vertical routing with one pipe system
Such a scheme can be installed even within one day; the old heating system is also being renovated here. At the same time, in a one-pipe system, it is impossible to control the flow rate of the coolant. In this case, the warm floor is connected to the central network through a riser. To implement this scheme, one of the radiators simply changes to the contour of the water floor in the room.
We recommend: How to connect a warm floor?
In this case, the temperature difference in the network and the circuit should not exceed 5-10 degrees. This scheme is considered dependent, since only one radiator in the room can be exchanged for a water floor. And the temperature is controlled by a circulation pump, which is controlled by a room thermostat.
Connection features
You can use the central network for more efficient heating; there is even an opportunity (with the appropriate permission) to even make a warm floor on the loggia. However, when implementing any scheme, the following nuances should be taken into account.
To the centralized system, the warm one is connected to the side inlets of the collectors, using special fittings. The screed under the topcoat should be three centimeters thick and reinforced with mesh; the latter is laid on top of PVC pipes.If a laminate is used, then additional insulation is not needed under it - this will only reduce the heat transfer rates. In places where pipes pass through walls, it is recommended to use corrugated pipes.
In no case should the heating medium circulating directly in the central network be used. Most of the used mechanisms and structural units withstand pressure from 1 to 2.5 atmospheres, while in the central system the pressure can rise up to 16 atmospheres.
Which scheme to choose depends on the area of the room. So, if the dimensions of the room exceed 30-35 square meters, then it is better to make several connections, but to different collectors.
YouTube responded with an error: Access Not Configured. YouTube Data API has not been used in project 268921522881 before or it is disabled. Enable it by visiting https://console.developers.google.com/apis/api/youtube.googleapis.com/overview?project=268921522881 then retry. If you enabled this API recently, wait a few minutes for the action to propagate to our systems and retry.
- Similar posts
- How is xl pipe underfloor heating installed?
- What materials are suitable for waterproofing a warm floor?
- How to choose a material for a warm water floor?
- What kind of underfloor mats are there?
- How to install a warm floor?
- How to install Eastec underfloor heating?
Floor heating connection diagram
To correctly connect the selected system, you need to prepare the equipment: a circulation pump, a servo drive for a warm water floor collector, a temperature control sensor, a distribution unit, a collector. Connection and test run of the system are carried out before the screed is poured.
The main thing in the system is the distribution unit, it regulates the temperature of the coolant.
Thanks to a three-way valve and a sensor (thermal head for underfloor heating), the owner of the apartment regulates the temperature, achieving optimal comfort and saving on bills. The essence of the valve with a sensor is the timely shutdown of the hot flow when the set temperature is exceeded.
A circulation pump is needed to evenly distribute the coolant in the system. The pump is installed after the distribution unit, but after the manifold group. From the three-way valve, cooled water enters the pump, then into the collector and along the contours of the underfloor heating. An air outlet and a drain valve are installed in the upper and lower parts of the manifold, respectively.
The diagram shows how to connect - underfloor heating to heating in apartments that close the heating circuit. If the tie-in is carried out in the apartments in the middle, then the three-way valve is replaced with a two-way valve.
Alternative underfloor heating Xl Pipe
Those who do not have the opportunity to legally connect floor heating from a battery should familiarize themselves with the modern Xl Pipe system. Reading reviews on xl Pipe underfloor heating, they note that this is a kind of hybrid of electric and water heating that does not have their drawbacks. The heating element here is a 2 cm diameter polyethylene tube filled with antifreeze. Inside the tube there is a chromium-nickel heating cable in a Teflon sheath.
The design is sealed and safe. The system does not use the pump, manifold, boiler. The coolant does not move here. Installation of liquid electric floor heating Xl Pipe is carried out in a screed. Furniture and equipment can be moved without restrictions, the system will not be damaged. As the reviews on the warm floor say as the main heating, this option copes with the task, the temperature can be adjusted at your discretion.
The essence of Xl Pipe is simple and straightforward. When turned on, the cable begins to heat the coolant, quickly reaching the set temperature. The fluid pressure in the system ensures an even heat distribution. According to the manufacturer, such a warm floor consumes one third less electricity compared to other electrical heating systems. When compared with water heated floors, the cost of purchasing a boiler, collector and other equipment is excluded.
Floor heating with Heat Life infrared film
Those who have no idea how to properly make a warm floor from heating, or are unable to carry out major repairs in the room for this, should take a closer look at the Heat Life IR heating film.It is used as a main or additional heating system in offices, residential buildings, industrial and other facilities. Those who choose Hit Life underfloor heating note the minimum installation and maintenance costs, low heating bills.
As a rule, the installation of the film does not require screed filling. It can be used to heat tiles, linoleum, laminate, porcelain stoneware, and other flooring options. Energy is used to heat the floor, not the air. In addition, infrared film can heat any surface - vertical, inclined, embossed. Even with mechanical damage to the film section, the overall system will continue to work. Corrosion to Heat Life film is not terrible.
Possibility of connecting a warm water floor to central heating
Such a possibility exists, however, it is limited to a certain extent by a number of legislative acts, and therefore, if you make an unauthorized connection of the warm water floor system to the battery circuit, as a result, you can get a number of problems with the governing bodies. In addition, if the ZhEK detects an unauthorized connection to the central heating system, residents will be charged not only with penalties, but a mandatory requirement to dismantle all equipment for warm water floors.
This is due to the ban on the change and subsequent modernization of existing utilities schemes in an apartment heated by means of central heating. First of all, when connecting a water floor heating system to the central line, the problem of temperature differences arises. That is, the temperature mark of the coolant in the pipes of the central heating main is in the range of 70-90 ° C, while the finish coating of the water-heated floor system is deformed and becomes unusable already at 50 ° C.
Along with this, there are a number of schemes according to which you can make the correct connection to the centralized heating system without harming the warm floor.
The scheme is based on the creation of a stationary heating unit in which a circulation pump will perform a key function. If the apartment has one outlet to the heating system, then the water heating system can be connected according to the principle of radiator batteries.
In order to equip a warm floor, you should select and purchase pipes. To position them on the base floor with a snake, corner joints are required, the use of which in some cases can badly affect the level of system reliability.
Due to the fact that after installation, the warm floor will be filled with a cement screed, in case of deformation of the pipe section, it will be necessary to completely dismantle the monolithic coating.
Another alternative scheme for connecting the water floor is carried out in the direction from the return pipe of the radiator to the heating circuit, for this you will need to install shut-off valves. The installation of a warm floor can be carried out with an orientation towards a closed system. All methods will be discussed in more detail below.
The disadvantages of connecting a water floor to a central heating system are:
- Illegal installation;
- High probability of breakdown of the heating system;
- The appearance in the system of the house of areas characterized by an uneven distribution of the coolant;
- Labor intensity of installation work.
The most suitable option will be the one in which the direct and return pipelines of the central system will enter the apartment. If the house has vertical distribution of risers, the heating point will disperse heat through the floor throughout all rooms. However, the amount of heat energy received from each riser of the central system will be strictly limited.
It is possible to connect a warm water floor to a central heating system according to a dependent and independent scheme.
Advantages and disadvantages of warm floors
Among the advantages of using water, electric systems, underfloor heating, they note savings on heating bills. If the feet are warm, even the lowest temperature can be perceived as comfortable. Installation is not complicated, the appearance does not attract attention, like standard heating radiators. There will be no drafts in a house with a warm floor. Children will not catch colds while playing on the floor.
As for the shortcomings, they also exist. Firstly, it is the cost of equipment, installation. Secondly, water-heated floors require a loss of several centimeters from the height of the room. Thirdly, the floors should be free of carpets - otherwise, why heat them. When a breakdown occurs, it is difficult to determine which area is damaged. Furniture should not cover the floor so as not to interfere with heat circulation.
Having familiarized yourself with all the above nuances, you can make a conscious conclusion about warm floors, the expediency of their use in an apartment as a main or additional source of heat. In general, electric floor heating systems are installed in small rooms - in the bathroom, kitchen, bathroom. If you plan to heat a spacious room, it is better to give preference to a water-based system. In any case, it is important to consult with professionals, who will subsequently be entrusted with the installation of the system, start-up and maintenance. This way you can get guarantees of the safety and durability of the system.
Heat exchanger circuit
100% of heating engineers will say that without breaking the law, you can create warm floors in an apartment with individual heating.
Despite the ban of public utilities on making any changes to the centralized heating system, experts have come up with a scheme that will create an autonomous CO, where an indirect heating tank (buffer tank, heat accumulator) and a heat exchanger will act as a heat generator.
This system does not in any way affect the design of the central CO, does not change the pressure and does not increase the hydrostatic resistance. The following equipment is indicated by numbers:
- 1 Circulation pump
- 2 Three-way mixer
- 3 and 4 Ball valves
- 15 Heat exchanger piping group, which includes: check valve; ball valve with sump.
Collecting a warm floor from heating in an apartment with your own hands according to this scheme is within the power of any home craftsman. For a clearer understanding of the assembly process, we recommend watching a video on the topic: