Dear customer!
You have purchased a gas instantaneous water heater with an electronic device
vom, allowing it to automatically ignite when you open the hot water tap.
The device has a digital indicator that allows you to control the temperature
a round of heating the water flowing out of the tap (only for model JSD20-W).
Thank you for choosing our water heater. When purchasing the device, check the completeness, and also require filling
sales organization of coupons for warranty repairs.
This instruction manual contains information on how to install
device, rules of use and maintenance, on safety measures during the operation of the device, the observance of which will ensure long-term trouble-free and safe operation of the product. Please read it carefully and follow the directions in it.
VEKTOR water heaters have all the necessary certificates and are allowed
to installation.
Installation of the device, instructing the owner on the principles of operation and rules
the operation of the apparatus, maintenance is carried out by the operational organization of the gas economy or other organizations, licensed
for this type of activity.
Checking and cleaning the chimney, repairing and monitoring the water supply system-
communications are carried out by the owner of the device or house management.
Responsibility for the safe operation of the machine and for keeping it in
the proper condition is borne by its owner.
If you have any questions about quality, you could not explain all the advantages
property of VEKTOR water heaters or did not explain the principle of operation, please contact the following phone numbers:
—
in St. Petersburg (multichannel)
—
in Moscow, 741-77-67
—
in Krasnodar, 68-09-52
Please be advised that the water heaters listed in this manual are designed
nerds for home use only.
Thank you for purchasing
our water heater!
Repair and settings of a gas column Vector
_______________________________________________________________________________
We installed the Vector gas water heater, started lighting it, and the wick goes out. There is a gas supply from the burner to both the wick and the splitter. As long as you keep the regulator on ignition, everything burns, as soon as you start letting go, the wick goes out. The middle metal pin is near the igniter, it is inside and heats up, but when the regulator is released, it goes out. I release the regulator smoothly, not abruptly. 1. Poor contact between thermocouple and solenoid valve - unscrew the nut on the back of the valve, look, clean, screw it back. 2. Faulty thermocouple - ring / measure voltage or replace. 3. EMC malfunction (coil breakage, dirt and grease on the EMC plate) - you will have to remove the valve, disassemble and watch. If you are sure of the normal contact of the thermocouple with a spring contact inside the valve and that the thermocouple is normally washed by the flame of the pilot burner, the column is two days old - make a warranty repair. Further actions require work with a multimeter and replacement of spare parts. Malfunction of the Vektor JSD 20 W gas column. Two days ago I connected this model and for some reason it flashes up only when the temperature is set to the maximum, that is, at 50 degrees and after 10 minutes it goes out. Can you please tell me what could be? Check the inlet pressure, draft in the flue duct.Switching off after 10 minutes is 99% insufficient chimney draft. The top of the column should not be heated above 40-50 degrees. Do not disconnect the draft sensor under any circumstances! If it starts only in the extreme position of the right handle, the inlet pressure is probably less than 1 bar. Check if the flow is regulated at all with the right handle. If the water is normal and there is a mechanical filter at the inlet, then it should work normally for 5 years. For columns with a generator, the presence of at least 100μm filter at the input is mandatory. Otherwise, the generator will fail over time. On the new gas column Vector Lux 20, when the gas supply is set to the minimum level, the gas supply is so strong that the possible water pressure is from strong (when the temperature on the sink mixer is 43 degrees) to very strong (if the tap is fully open, then the temperature on the mixer wash 41 degrees). The water regulator is also set to the minimum level. Switching to summer mode will only decrease 2 degrees. To obtain t 36 degrees, you have to close the valve on the gas pipe by more than 3/4. Also, in a week after installation, the thermometer went off twice, showed a temperature of 10 and 5 degrees more, after that the correct display was restored. You need to measure the water flow with a bucket / stopwatch. No one promised that the Chinese have a huge range of temperature control. In summer the temperature of the incoming water is higher and the head must be higher. Usually, when using such a column, the hot water tap must be opened completely. What will be the pressure, this will be. Gas column malfunction Vector. It worked for 5 years, then within 3 days it began to go out, then it stopped lighting up. They removed the casing, a hole burned out in the heat exchanger. They put the same new one, it does not light up. The batteries are new and the water pressure is good. When the water is opened, the ignition works, the micrik opens, the gas valve relay does not work. How to forcefully open the gas valve (three wires: red-yellow-black). Is it possible not to turn on the column due to low gas pressure? Elementary, but more often this happens out of stupidity. Forgot to open the gas cock. The gas valve was not fully opened (it should be 90 degrees. No more / no less). An excessively narrowed GPU was used, or the gasket was installed with a small bore. The "correct" passage in the narrow place of the gas HZ (in the fitting; and so that the gasket does not constrict) is at least 13 mm. Our speaker Vektor Lux one day just stopped turning on: I thought about batteries, bought new ones, it still does not burn. The device is more than 8 years old, has never let down, but here there are no clicks, nothing, silence, as if not connected. Tell me what to do? See the membrane. Further - oxidation - from the battery pack and further along the wires / connectors / mikrik. The geyser Vector Lux eco is in operation. 5 months in operation, stopped igniting, are the batteries normal? What can? Anything can be. On the part of the membrane. If, when the water is opened, the plate moves away from the microswitch, the membrane is intact. Look for poor contact in mikrika / wires / batteries. Is there a switch at the bottom of the column? Either it is turned off or failed (weak link), you can remove it, there are connectors inside that can be connected to each other. When the hot water is turned on, the ignition starts to click, and the gas does not open, but if you open the hot water. water to full, then the gas still opens and then you can reduce the water - everything works. How can this be related? I thought that if the micrik works and the ignition starts to click, then it means that the water pressure is sufficient and at the same time the gas should open? I changed the batteries - it did not help. The geyser Vektor JSD20-W, before that worked for 1.5 years, the oddities began after replacing the water-gas unit. I want to check the operation of the e / m valve, but there are three wires coming from it - I don’t know which ones to supply power to. It is very easy to check the valve, apply 3 Volts to it, along the wires that it is going through now.It is fastened with two screws, and can be removed for visual observation of the work. Just do not forget to close the gas valve before doing this. Disconnect the connector, and measure whatever you want. By the way, there not only the solenoid valve opens the gas, but is also duplicated mechanically, the stem opens another valve, it is inside the gas block. It can be reached by unscrewing the two screws connecting the gas block to the water block. But there the reason is very, very rare. Start with the solenoid valve. The Vektor lux Eco gas water heater is in operation, age 4 years. A few days ago, I started to junk. It ignites only when you strangle the water on the column. Then it began to fade during operation. The water regulator had to be twisted almost all the way to the right. In this case, the pressure in the network is normal. Disassembly from a water heater for 2 points. Began to light up only when you use the farthest point. Cleaned the mesh filter. I thought what happened to the mixer. Disconnected the hot water supply to the mixer. In this case, it ignites and works normally. True, with an increase in the flow of water through the column, it still tends to go out. The mixer has been checked, everything is normal. In a minute, 10 liters from the apparatus easily pass through it. What does she want? I myself sin on the membrane. Most likely, you need to replace the membrane (it may be intact, but stretched). And also clean and lubricate the stem. Help with a diagram or advice on repairing a gas column Vector. The display lights up constantly. It lights up only when the battery is turned off / on. The device has a micro button. When you remove the case, it is in the middle in front of you immediately. The problem is her. Fold in the plate that is it. Presses, or it is necessary to replace the rod, which activates the mechanism on the button. Installed a geyser Vector Lux Eco in the kitchen. I turn on the gas, the water flows at full, then I reduce the stream to half - the column works, the flame also decreases, everything is fine. But if I want to set the jet to a minimum, the water heats up to 75C somewhere and the column is simply cut off. Something is not good at all, what should I do - change the device? Most likely, the matter is in the discrepancy between the calculated pressure for the gas and your pressure in the system. That is, the water heater operates in high power mode. It is not good. What can be done is to try to adjust the gas supply valve, it's definitely in it. If it can be adjusted, it means that the pressure and temperature can be done as it should. Malfunction of the Vektor JSD 20 W geyser, lights up from the 5-6th time. After 15-20 minutes of operation, it goes out by itself. Who faced this problem? What solutions are there? Check the ignition of the column with an open window. Because air enters the kitchen through an air duct located at the same height as the chimney on the roof. If it also goes out when the windows are open, then the traction control device must be changed. Tell me I have such a problem: when the water is turned off, the column ignites itself, the temperature rises and does not turn off (I had to remove the batteries), I put the batteries back (I do not turn on the water), it lights up, what should I do? Either the microswitch has closed or the membrane has broken. Contact a specialist. How to make email did the solenoid valve and this mechanical valve open at the same time? I mean tweak the mechanics, not the micrik? otherwise it looks like e-mail. the magnetic valve opens earlier than the mechanical one. Algorithm of work: When the hot water tap is opened, the membrane of the water block bends and moves the water stem. block. The stem opens the gas valve to the burner and at the same time closes the microswitch. The current goes to the control unit. This is followed by a spark discharge for 7 seconds. At 2-4 seconds, a signal is sent from the control unit to the solenoid gas valve. The valve opens. When a flame appears, the spark stops. Check the water block and the moment the micrik is turned on. Check all contacts.The malfunction of the Vector gas column has been in operation for more than 3 years, and there were no problems. Only recently, as they began to show the discharge of the battery, it stopped turning on. When I bend the plate to microvolts. then lights up. I thought the trouble was in the batteries, I changed the Camelion batteries, my old ones, too, were the same for exactly a year and a month, but it still stopped turning on. If there is no ignition: the batteries are new, there is water pressure; it is necessary to check the operation of the microswitch. To do this, remove the casing: pull out 3 handles, unscrew 2 screws below the column: left and right. We pull the bottom of the device towards ourselves by 2-3 cm and lift the casing up to the exit from the pins at the top. The cover is removed. There is a mikrik in the center at the bottom. Supply water, the switch button will be released by the lever and should come out of the recessed state, if it does not come out, help with a screwdriver and lubricate with oil. I went firing up. We installed a Vector JSD 20 geyser, today it began to drip inside from where we don't know who can and understands tell me what that is, just somehow it was not clear yesterday everything was fine, today it started to drip. Check the gaskets, only two screws need to be unscrewed! We have installed the vektor JDS 20-2 gas water heater and am struggling with it. With a low flow, it heats the water up to 45-50 degrees. The gas supply (regulator knob) is at a minimum. I don’t know what to do. Any tips? In front of the column, on the gas pipe, there is a valve to shut off the gas supply. Here, slowly reduce them to the desired temperature. We installed a Vektor Lux Eco JSD gas water heater, the water pressure is excellent, but the temperature on the display shows 58 degrees, and the water flows like a river. What could be the problem? Remove the casing from the column, there is a black microswitch, three wires fit to it - red, green, yellow, this is between two gas and water regulators. If you look closer, on the microswitch, there will be a plate, which, when water is supplied, presses on the switch and the pieza is triggered and the column turns on, but it presses strongly on the switch, and therefore the water pressure is not enough, it will turn on, the plate on the switch must be bent until then when the switch starts to operate on the water flow. But before this work, close the gas, just see how the piezo will work with the opening of the tap. Tell me what the problem is. When you open the tap mountains. water there is no spark discharge, the device does not turn on, the batteries are in good order. Provided that the membrane, contacts are in good working order, and if the stem is not soured (you can check by the bracket - when you open the tap, the bracket opens the contact between the microswitch, when you close the tap, it goes into place). Change microswitch. Malfunction of the gas column Vector 20. Powered by bottled gas. 4 months there were no problems. Then the gas stopped lighting up. I changed the batteries, zero. Cleaned the input filter, the effect is the same. The battery clicks, but there is no gas ignition. The gas pressure is good, the water pressure is good, but the water is not heated. What to do? A device with a chimney. There is also a draft in the pipe. Replace the gas valve. The Vektor Lux gas water heater is in operation, without a chimney. Everything would be fine, but when the water is turned on, the electric ignition is triggered immediately and does not stop working, and after a while the electric ignition is cut off at the same time the column goes out. Hot water, respectively, comes in very little. The total burning time is up to 30 seconds. What is the reason? Open the device. In front of you there will be two piezo ignition, one flame sensor. The flame sensor is longer, file it until it shines and correct the contact. Tell me why water does not pass through the heater well, there is good pressure up to it, but a small stream of water runs from it. Try to clean the mesh at the entrance.
_______________________________________________________________________________
_______________________________________________________________________________
_______________________________________________________________________________
- Gas boilers
- Electric boilers
- Gas water heaters
- Malfunctions and repair of gas water heaters
- Water heaters
- Boiler error codes
- Elimination of malfunctions in boilers
- Troubleshooting water heaters
- Repair of indirect heating boilers
- Elimination of malfunctions in electric convectors
_______________________________________________________________________________
- BOSCH THERM 4000
Models WR-13, WR-13. Specifications. Installation. Maintenance and adjustments.
- NEVA 4510
Construction and main components. Installation and connections.
- NEVA 4511
The purpose of the main nodes and elements. Maintenance and replacement of parts.
- NEVA 4513
Adjustments and settings. Service maintenance.
- NEVA
Design features. Malfunctions and maintenance.
- NEVA LUX 5514
Elements and components. Installation and assembly. Operation and adjustments.
_______________________________________________________________________________
_______________________________________________________________________________
- NEVA REPAIR
The gas water heater Neva VPG-12E is in operation, after turning on the hot water tap, the column lights up, but the temperature does not rise above 20 degrees. The water pressure is normal, it does not respond to the flame increase regulator, as it was 18-20 degrees, it remains. What could be the problem?
- ARISTON
I connected an Ariston Marco Polo Gi7s column. Everything is working. But the device is turned on the second time. That is, you turn on the water, the column starts up, clicks and goes into the E1 error. Then he closed the tap, opened it and it starts up. Powered by a balloon. Is this possible because after her work I turn off the gas?
- ELECTROLUX
Malfunction of the Electrolux 275 gas column, you turn on the hot water, everything lights up and works for 5-7 minutes after which a click occurs in it and it goes out together with the igniter. Tell me what is the problem?
_____________________________________________________________
- OASIS
Malfunction of the Oasis TUR 20 gas water heater. In the "Summer" mode, the gas and water regulator is at maximum. It goes out by itself, when after 5 minutes, when after 30. In the "Winter" mode, with any combination of regulators, it goes out after 30-40 seconds. What can be wrong? Water supply with flexible hoses. Could they be the cause? If so, what to replace?
- VECTOR
Tell me I have such a problem: when the water is turned off, the column ignites itself, the temperature rises and does not turn off (I had to remove the batteries), I put the batteries back (I do not turn on the water), it lights up, what should I do?
- ASTER
Help me find the reason, the Astra 8910-02 gas water heater, when hot water is on, it goes out from time to time, I cleaned the thermocouple to shine, the membrane is in good condition, but just in case replaced it with a new one, the water pressure is less than that of cold water, what else note?
- BOSCH
I installed and put into operation a Bosch WR 13 gas water heater. I moved the nozzles to liquefied gas, remove the jumper from j6, that is, switched to liquefied gas mode, but the column does not work, who knows what about this? When turned on, the green button lights up for a couple of seconds, and then the red starts blinking and only the fan turns on.
- JUNKERS
The Junkers gas water heater began to malfunction. It works for 15-20 minutes and goes out. You turn off and turn on the water, the igniter lights up, and after a few seconds it goes out, and you can do this at least how many times, it does not ignite. A little time passes - it works, and again everything repeats itself. The water pressure is good, the gas pressure too. What could be the reason?
SAFETY PRECAUTIONS …………………………… ..
Page 3
- Picture
- Text
3
CONTENT
SAFETY PRECAUTIONS ………………………………………………………………… 4
DESCRIPTION AND OPERATION OF THE PRODUCT …………………………………………………………………… .. 5
2.1 Purpose of the product ………………………………………………………………………………… .. 5 2.2 Technical characteristics ……………………… …………………………………………………. 5 2.3 Product composition …………………………………………………………………………………………. 5 2.4 Description of the apparatus and the purpose of the main units …………………………………………. 8 2.5 Overall and mounting dimensions …………………………………………………………… ..9 2.6 Electrical diagram ……………………………………………………………………………… .. 12
INSTALLATION PROCEDURE ……………………………………………………………………………… .. 13
3.1 Installation site ………………………………………………………………………………………. 13 3.2 Installation of the device …………………………………………………………………………………… .. 13 3.3 Water connection ………………… ………………………………………………………………… .. 14 3.4 Gas connection ………………………………………………… ……………………………………. 17
3.5 Connecting the device to a bottle with liquefied gas ……………………………… .. 17
3.6 Installation of a flue gas flue (except for model JSD11-N) 17 3.7 Installation of a JSD11-N water heater (without connection to a flue) ………………………………………………………………………………………………………………………………………………………………………………………
USING THE MACHINE ………………………………………………………………………. twenty
4.1 Switching on the device ………………………………………………………………………………… 20 4.2 Regulation of the degree of water heating ……………………… …………………………………. 20 4.3 Switching off the device for a long time …………………………………………… .. 21 4.4 Protection against freezing ……………………………………………… ……………………. 21
MAINTENANCE ……………………………………………………………… .. 22
5.1 Inspection ……………………………………………………………………………………………………. 22 5.2 Care ……………………………………………………………………………………………………… .. 22 5.3 Maintenance… ………………………………………………………………………. 23
5.3.1
Cleaning the burner
…………………………………………………………………………………………………………. 23
5.3.2
Cleaning water and gas filters
………………………………………………………………………………. 23
5.3.3
Cleaning the heat exchanger
…………………………………………………………………………………………. 23
5.3.4
Replacing sealing joints
…………………………………………………………………. 24
5.3.5
Checking the tightness of the gas and water systems of the apparatus
……………………… 24
5.3.6
Checking the performance of the thrust sensor
………………………………………………………. 24
5.3.7
Checking the performance of the heat exchanger overheating sensor
…………….. 24
5.3.8
Extraordinary cleaning of the machine
……………………………………………………………………………. 24
5.3.9
ODS sensor performance check (for model JSD11-N)
POSSIBLE MALFUNCTIONS OF THE APPARATUS AND METHODS OF THEIR ELIMINATION…. 25
STORAGE RULES …………………………………………………………………………………. 27
WARRANTY ………………………………………………………………. 28
CERTIFICATE OF ACCEPTANCE ……………………………………………………………………… 28
10 NOTICE ABOUT INSTALLING THE APPLIANCE AND PERFORMING MAINTENANCE ………………………………………………………………………………………………………………………………………………………………………………………………………………… 29
Benefits of choice
Consumers note many positive aspects of Vector geysers. The first is their cost. Water heaters under the specified brand are classified as relatively cheap equipment.
Secondly, buyers are attracted by the compact size and stylish design of Vector geysers, thanks to which they will perfectly fit into any interior.
Thirdly, the presence of a digital display, ignition in automatic mode and a copper heat exchanger greatly facilitate the control of gas equipment.
Fourth, the latest models of Vector columns are equipped with a temperature control system. The main criterion in this case is the season. It should also be noted protection against overheating, smoke exhaust system, ease of installation and power.
W dimensions overall and mounting ...
Page 10
- Picture
- Text
10
Fig. 2b. Vektor JSD12-W dimensions overall and mounting