Floor standing boiler Konord KSts-GV-16S with SIT automation (double-circuit)


Boiler overview

gas boilers conord reviews

If you decide to purchase gas boiler equipment from, then you must be prepared for the fact that all models of this supplier are floor standing. Their dimensions are quite large, and the outer casing has a protective enamel. Additional characteristics include 3-mm steel at the base of the case, as well as the ability of the equipment to maintain the desired temperature regime.

The efficiency of the units reaches 90%. They are non-volatile and presented for sale in several modifications. Some models have the ability to prepare hot water for consumption. The units can be of thermohydraulic type automation or SIT system. The first option deals with non-volatile devices. The shutdown and fuel supply is controlled by a thermostat. When the temperature near the device reaches a certain parameter, gas stops flowing to the main burner, this allows you to maintain the required temperature regime.

Gas boilers "Conord", reviews of which you can read in the article, are well adapted for operation in conditions of not only severe, but also warm winter. They maintain the set temperature with the correct power calculation. The burner is installed with good quality, due to which good productivity is achieved, an optimal gas-air mixture is created and thermal insulation is provided. Due to these features, the gross volume of heat is spent on heating water.

Security systems

double-circuit boilers

Floor standing gas boilers "Conord" are safe and have several systems responsible for this. Among others, a smoke exhaust sensor should be highlighted, which is triggered in the absence of draft, it turns off the gas supply to the burner, as well as if a short-term reverse draft occurs. Such conditions can occur with intense gusts of wind.

The flame on the burner is constantly monitored. If not, then the gas supply is suspended. The temperature in the heating circuit is monitored. Heating of the coolant stops when the temperature reaches a certain value. The described devices function perfectly even at low fuel pressure.

Operation of the gas boiler "Conord"

On the Internet, you can find many reviews about the acceptable cost and reliability of the Conord gas boiler. But you can also see negative reviews, which are most often associated with the extinction of the boiler for no reason. This problem can arise for several reasons:

  • There is not enough air for normal operation of the pilot burner. In order to fix this, it is necessary to clean the air supply nozzles, and also check the ventilation in the room;
  • Burner dirty. In this case, the air and gas nozzle must be cleaned. This can be done with a brush or vacuum cleaner;
  • Defective flame sensor or draft sensor;
  • The thermostat contacts have oxidized. With such a problem, you should stir or clean the contacts;
  • Most problems can be fixed on your own, while in other cases you will have to use the help of a specialist.

The temperature of the heat carrier in the system may drop significantly. To eliminate this problem, turn the thermostat switch to the maximum position, and then increase the gas flow to the burner. This can be done if it is indicated in the instructions for the gas boiler.

During the summer period, it is necessary to perform some actions for the boiler to work. To turn off the heating circuit, turn off the tap on the water supply.When the pilot burner is operating, the water will heat up to 60 degrees within 1 hour. After the boiler has warmed up, it can be turned off if an active flow of warm water is not needed. Otherwise, the water may boil and the boiler will be damaged.

Overview of marking and its decoding

floor standing gas boiler conord

You can find out about some technical characteristics of the boiler if you pay attention to the marking. It may look as follows: KSC-G-10S or KSC-GV-12. The letter "K" stands for "boiler". The fact that it is made of steel is indicated by the letter "C". If the design of the firebox is cylindrical, then you can find out about it by the letter "C".

Gas boiler equipment is designated by the supplier with the letter "G". If in front of you is a boiler that provides the function of hot water supply, then you can find out about this by two letters - "GV". After the letter designation, you will see numbers. They indicate the maximum power level.

In order to determine the required power when buying a boiler, the area of ​​the room is taken into account. For every 10 m2, 1 kW of power will be needed. This is true if the ceiling height is 2.5 m. It is important to take into account that this choice is relevant for an average level of heat loss.

Boiler device

gas boiler conord price

The device of the gas boiler "Conord" provides for the presence of a furnace, which is made of 3-mm steel. The design has a water jacket, a gas burner device, and smoke tubes with built-in turbulators. The latter are necessary to increase the efficiency.

As for the gas burner device, it is an automation. The unit has a thermal insulation layer made of basalt cardboard. The device has a thermometer to control the temperature of the water. In double-circuit models, there is a coil for the water circuit around the chimneys.

The outlet and inlet of the coolant from the hot water coil is located on the back of the case. The diameter of the thread of the heating pipes is 2 inches, which is equal to 50 mm. For a hot water circuit, this parameter is ½ inch or 15 mm.

Gas boiler for heating "Conord" has a chimney, the diameter of which can be equal to 115 mm. This is true for models that range from 8 to 12 kW. If this value is increased to 16 kW, then the corresponding diameter will be 150 mm. Due to the fact that the design provides good thermal insulation and has built-in turbulators, the efficiency reaches 90%.

These units are capable of operating at reduced gas pressure and are non-volatile, therefore they will operate without electricity. Gas boilers "Conord", reviews of which must be read before buying such equipment, are supplied by the manufacturer with a 15-year warranty for the service life. As for the factory warranty, it lasts for 3 years.

How to install a gas boiler "Conord"

In order for you to be able to use the warranty card, you must entrust the installation, adjustment and commissioning of the boiler to specialists from the service center. In addition, they are obliged to make an entry in the technical passport of the boiler. Do not forget about the annual inspection of equipment by specialists for prevention. It must also be indicated in the technical passport of the gas boiler. Failure to do so will void the hardware warranty.

Some features should be taken into account when installing an electric boiler:

  1. It is necessary to locate the lower branch pipe below the heating radiators for normal water circulation in the system.
  2. To install the boiler on a combustible floor, it is necessary to arrange a non-combustible substrate. It should be 50 cm larger than the equipment on each side.
  3. The uprights must be placed vertically.A deviation of 3 meters of the structure is possible - 3 mm.
  4. Various pipes can be used for the system. When welding joints, it is necessary to leave the threaded joints for repair work.
  5. Bends with a slope for each meter of pipe by at least 1 cm should be arranged to the heating device.
  6. For air venting, horizontal sections should have a slope of 1 cm per meter.
  7. The equipment must be connected to the chimney, which is located in the load-bearing wall of the building.
  8. Shut-off valves must be installed at the outlet of the coil.
  9. The diameter of the chimney must be larger than the diameter of the pipe for stable operation of the equipment, as well as for sufficient draft.
  10. It is necessary to protect the unheated area through which the chimney passes with thermal insulation.
  11. The device, height and parameters must be observed taking into account regulatory documents and fire safety requirements.
  12. The chimney must be executed vertically without any ledges.
  13. Before installing a gas boiler, the project should be agreed with the relevant authority.

Review, reviews and characteristics of the most popular models

characteristics of gas boilers Conord

Floor-standing models from are made of high-quality steel, the surface of the case is protected by a heat-resistant powder composition. The equipment is produced in 4 series. One of them is designated by the KSC-G-S marking. In this case, we are talking about single-circuit devices that are equipped with SIT automation.

This is a multifunctional regulator that is responsible for the gas supply. Equipment power can range from 8 to 30 kW. The temperature can be adjusted between 60 and 90 ° C. The minimum pressure level is 0.2 bar, while the maximum value is 1.9 bar. The price of the gas boiler "Conord KSts-G-8S" is 10,500 rubles.

Reviews of boilers of the KSts-G-N line

boiler gas conord ksc

Another series - KSts-G-N, which includes single-circuit boilers with thermohydraulic automation. The power range varies from 10 to 30 kW. To increase the efficiency of the work, the structure has a cylindrical shape of the heat exchanger made of cold rolled steel. The unit is capable of operating at pressures up to 5 bar.

Considering the characteristics of "Conord" gas boilers, one should not forget about their cost. For example, you can purchase the KSts-G-10N model for 11,600 rubles, which, according to users, is an affordable price.

Technical characteristics of gas boilers "Conord"

The main technical characteristics of gas boilers of this brand can be distinguished:

  1. Nominal service life from 15 years.
  2. 3 year warranty.
  3. Boilers equipped with a cast iron heat exchanger can have a service life of 25 years.
  4. Antifreeze must not be used.
  5. Heat exchangers are made of cold-rolled metal, which is why they are not subject to thermal deformations.
  6. Water from the water supply system is used as a heat carrier.
  7. The boiler can be used with or without a circulation pump.

Reviews of boilers of the KSts-GV-N series

Double-circuit boilers from are also represented by the KSts-GV-N series, which is offered in models with thermohydraulic automation. The minimum power is 12 kW, while the maximum level is at the same limit.

The design of the smoke collector is unique, it has a corresponding sensor, which is responsible for shutting off the gas supply in the absence of draft. With a short-term reverse draft, the stabilization of the boiler operation is ensured by the same sensor. You can purchase double-circuit boilers of this series for 15,000 rubles. This cost, according to consumers, is a little overpriced, but justified by decent quality.

User's manual

To avoid loss of warranty, the manufacturer does not recommend installing and repairing boilers on their own. This can only be done by specialists with special qualifications for working with gas equipment.Service workers will be able to qualitatively install and configure the boiler, turn it on and test it, check its performance. After installation, they must make an entry in the passport, after which the boiler operation is prevented once a year. After each prophylaxis, a corresponding mark is made in the technical passport. In the absence of entries in the document, the manufacturer has the right to void the warranty.

Reviews about the features of the choice

Gas boiler "Conord KSC" can be single-circuit or double-circuit. The power varies from 8 to 30 kW, which, according to buyers, gives a big run-up for selection. Among the single-circuit models, the following should be distinguished:

  • KSC-G-8.
  • KSC-G-12.
  • KSC-G-20.
  • KSC-G-30.

Whereas if you want to choose a two-circuit model, you can pay attention to the following equipment options:

  • KSts-GV-10.
  • KSC-GV-16.
  • KSC-GV-25.

Consumers are advised to choose single-circuit models for heating areas ranging from 30 to 300 m2. Double-circuit models are good because they can be used not only for heating, but also for hot water supply. If you need to purchase a two-circuit model, it is better to prefer the equipment option, the power of which varies from 20 to 25 kW. The device will dispense about 12 liters of hot water per minute. It is impractical to purchase KSts-GV-12, the power of which is mentioned in the marking, if it is necessary to obtain hot water in a large volume. Consumers like that the described equipment can be used in both open and closed heating systems.

iwarm.decorexpro.com/en/

Warming

Boilers

Radiators